We use cookies on this site to enhance your user experience. By clicking any link on this page you are giving your consent for us to set cookies.
Loading
誼信科技有限公司
  • ( English )
    • English
    • 繁體中文
    CLOSE
  • ABOUT US
  • PRODUCT
    • Back
    • Cabinet Smoke Detectors
      • Back
      • CSD-100
      • CSD Duo
    • Aspirating Smoke Detectors
      • Back
      • QUARTAS Series
      • FANFARE Series
    • Networking
      • Back
      • NIM Interface Module
      • NCP Control Panel
      • AMS Software
    • Peripheral
      • Back
      • APS Power Supply
      • ASH Strobe Horn
      • ASM Sensor Modules
      • PASD Portable ASD
      • Demo Kit
    • Pipes & Accessories
      • Back
      • Pipes, Fittings and Accessories
    • OEM/ODM
      • Back
      • Private Label
      • Core Modules
      • New Design
  • TECHNOLOGY
  • APPLICATION
    • Back
    • Overview
    • Normal Environments
    • Electrical Cabinet
    • Data Center/EDP
    • Cleanroom
    • Warehousing
    • Harsh Environment
    • Heritage
    • Duct Detection
  • SUPPORT
  • WHAT'S NEW
    • Back
    • News
    • Blog
    • Application Notes
  • ( English )
    • Back
    • English
    • 繁體中文
  • Copyright © 2017 MIRACLE
Duct Detection
  • Our price:USD$
  • PriceUSD$
  • Use bonus pointspt.

Duct Detection

There are two principle applications for sampling smoke from a duct using ASD; either as a DSD to prevent smoke spread or to provide early warning of a fire condition in an area or piece of equipment from which air is extracted.

Within these applications there are a number of issues to be considered when designing a duct detection system using ASD. The primary ones being:

  • Pressure equalisation
  • Maintenance accessibility (Flexible joints to allow the pipe to be removed)
  • Monitoring upstream or downstream of filters, (generally on the upstream side)
Monitoring is achieved by installing sample pipe within the duct. To maintain the pressurisation balance the exhaust sampled air is returned to the duct downstream of the monitoring sample pipe. To provide the ASD with a maintenance facility it is recommended that the sample pipe span the width of the duct and protrude the opposite side and be capped. This will allow test smoke to be introduced at this point for commissioning and maintenance purposes. Typically as ducts have different pressures it is recommended that only a single ASD monitor a single duct.

Sampling pipe installed within the duct will require the sample points positioned at an angle of 30- 60º off centre, into the airflow, unless directed otherwise by the ASD manufacturer. It is recommended that each sample point shall have a maximum area coverage of 0.4m2 of the cross sectional area.

The use of a union socket is recommended to allow the selection of the final orientation during the commissioning of the system. Where possible the sampling pipe should be installed in the centre of the airflow and away from bends. It is also recommended that the sampling pipe be installed close to inspection hatches for maintenance purposes. Due to the use of High Efficiency Particle Arrestor (HEPA) filters within HVAC systems, it is recommended that monitoring be carried out before the filter, as smoke particles may also be removed by the filter.

Due to the dilution of the smoke particles from the protected area, due to high airflows, it is recommended that only Class A & B ASD’s are suitable for early warning applications.

Note: The preliminary European product Standard for DSDs (prEN 54-27) defines ASD as a type 5 DSD and requires that they are approved to EN 54-20

Back to the top
  • Our price:USD$
  • PriceUSD$
CONTACT
AVA PREVENT CO., LTD
Rm. 4, 2F., No. 700, Zhongzheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.)
+886-2-8228-0508
inquiry@ava-prevent.com
  • LINE
  • YOUTUBE
  • LINKEDIN
TOP
 
256 bit SSL Encryption
Recommend using Chrome, Firefox, Safari latest version of the browser.