We use cookies on this site to enhance your user experience. By clicking any link on this page you are giving your consent for us to set cookies.
Loading
誼信科技有限公司
  • ( English )
    • English
    • 繁體中文
    CLOSE
  • ABOUT US
  • PRODUCT
    • Back
    • Cabinet Smoke Detectors
      • Back
      • CSD-100
      • CSD Duo
    • Aspirating Smoke Detectors
      • Back
      • QUARTAS Series
      • FANFARE Series
    • Networking
      • Back
      • NIM Interface Module
      • NCP Control Panel
      • AMS Software
    • Peripheral
      • Back
      • APS Power Supply
      • ASH Strobe Horn
      • ASM Sensor Modules
      • PASD Portable ASD
      • Demo Kit
    • Pipes & Accessories
      • Back
      • Pipes, Fittings and Accessories
    • OEM/ODM
      • Back
      • Private Label
      • Core Modules
      • New Design
  • TECHNOLOGY
  • APPLICATION
    • Back
    • Overview
    • Normal Environments
    • Electrical Cabinet
    • Data Center/EDP
    • Cleanroom
    • Warehousing
    • Harsh Environment
    • Heritage
    • Duct Detection
  • SUPPORT
  • WHAT'S NEW
    • Back
    • News
    • Blog
    • Application Notes
  • ( English )
    • Back
    • English
    • 繁體中文
  • Copyright © 2017 MIRACLE

QUARTAS Series

QUARTAS Single Detector

Very Early Warning Aspirating Smoke Detector

 

QUARTAS-500s

Single Pipe
Aspirating Smoke Detector
 
Max. no. of Sampling Holes
- Class A 40
 - Class B 60
 - Class C 60
  Max. Sampling Pipe Length
 - Single Pipe 100m 
- Two Brached Pipe 2 x 80m
- Four Branced Pipe 4 x 60m

 


QUARTAS-2000s

Four Pipes Scanning
Aspirating Smoke Detector
 
Max. no. of Sampling Holes
- Class A 40
 - Class B 60
 - Class C 100
  Max. Sampling Pipe Length
 - Single Pipe 4 x 100m 
- Two Brached Pipe 4 x 2 x 80m

QUARTAS-2000s Pipe Scan

Taking advantage of the four individual aspirators in the QUARTAS-2000s, in case of fire it can turn on and off each aspirator in sequence to “identify” the pipe having the most smoke.

Read More

BLUE LED DETECTION

► High Power Blue LED Light Source

► Wide Angle Nephelometer Mass Detection

► Maximum  Detection  Sensitivity 0.001%/m

► Maximum Alarm Sensitivity 0.005%/m
 
 

MULTIPLE FUNCTION DISPLAY/ PROGRAMMER

►Display
 
  • Smoke, Flow, Address, Event/Error Code
     
  • 20 Segments Smoke Bargraph
     
  • Alarm and Fault Indicators
 
► Control
 
  • ​Reset/Isolate/Silence/Test Buttons
 
► Programmer

 
 

QUARTAS-500s
Tyipical Applications

  • Internet Data Center
  • Computer Room
  • Telecom Room
  • Control Room
  • Electrical Room
  • Air Conditioning Facilities
  • Cleanrooms
  • Railway Coach
  • ESS Energy Storage System 

 

QUARTAS-2000s
Typical Applications

 

  • Warehouse/High Bay Wareshouse
  • Distribution Center
  • Airport
  • Transportation Station
  • Mueseum/Gallary
  • Cleanrooms
  • Electrical Room 

ASD Specifications

Items QUARTAS-500s QUARTAS-2000s FANFARE-2000 FANFARE-4000
  Detection Light Source High Power Blue LED
Detection Principle Forward Light Scattering
Detection Sensitivity Range 0.001~25 % obs/m
Alarm Sensitivity Range 0.005~20 % obs/m
Alarm Level 4 Stages (Alert, Action, Fire-1, Fire-2)
Alarm and Fault Time Delay 0~60 (Sec.)
Sensitivity Switch 2 (0.1~10)
Flow Learning 6 Flow Sensitivity Learning Mode
Environment Smoke Learning 15 / 60 / 120 / 240 / 480 minutes (Non-Stop)
Fan Speed 10 Steps Adjustable
High Sensitivity Smoke Chamber 1 1 4 8
High Efficiency Aspirator 1 4 4 8
Flow Sensor 1 4 4 8
Air Sample Inlet Port 1 4 4 8
Air Sample Exhaust Port 1 1 4 8
Two Stages Filter 1 1 4 8
Local Display / Programmer Numerical Value Display Smoke Level / Flow Level / Address / Event Code and Aux. Sensor Level (if fitted)
Bargraph 20 seg. Bargraph x 1 20 seg. Bargraph x 4 20 seg. Bargraph x 8
Indicator LED 10 (OK / Isolate / Alert / Action / Fire 1 / Fire 2 / Det'n / Flow / System /Aux.) 6 (OK / Ioslate / Det'n / Flow / System / Aux.) + 6x4 (Fault/Alert/Action/Fire 1/Fire 2) 6 (OK / Ioslate / Det'n / Flow / System / Aux.) + 6x8 (Fault/Alert/Action/Fire 1/Fire 2)
Control Buttons   6 (Reset / Silence / Isolate / Test / Left / 
Right)
8  (Reset / Silence / Isolate / Test / Left / 
Right / Up / Down)
Beeper Yes
Programmer LED Type LCD Type
Remote Display / Programmer Numerical Value Display NA
Bargraph
Indicater LED
Control Buttons
Beeper
Programmer
RS485 Network Yes
RS485 Repeater Yes (Extend 1,200m)
General Purpose Input (GPI) 4 (Configurable) 8 (Configurable)
Relay Output 7 (Configurable)
Zone Relay NA 16 relays (optional) 16 relays 32 relays
Auxilliary Sensors Optional (Temp./Humidity and Gas Sensors)
Event and Data Logs 180,000 (items)
Sampling Pipe Length Total Pipe Length 240m  640m 640m 1280m
Single Pipe Length Single Pipe 100m, Branched Pipe 160m
No.  of Sampling Holes Class A / VEWFD 40 Holes 40 Holes 40x4=160 Holes 40x8=320 Holes
Class B / EWFD 60 Holes 60 Holes 60x4=240 Holes 60x8=480 Holes
Class C / SFD 60 Holes 72 Holes 400 Holes 800 Holes
Maximum Coverage 500m²;Max 1,000m² 2,000m² 2,000m² 4,000m²
Sampling Pipe Specification OD:Φ25mm/ID:Φ21mm
Capiliary Tube Specification OD:Φ8/ID:Φ5
Operating Voltage 24Vdc ±6 
Operating Current 350mA 730mA 1.13A 2A
Ambient Temperature 0~50°C
Max. Temperature under Sun 70°C
Sampling Air Temperature -20~60°C
Operation Humidity 0~95%RH, Non Condensing
Dimensions (W x H xD) 215 × 202 × 85mm 415 × 259 × 108mm 426 × 291 × 130mm 670 × 291 × 130mm
Weight 1.5kg 5.2kg  7.5kg   12.1kg  
Note: Specifications are subjected to change without notice.